FEATURES
Application
Used as a test data transmission signal cable, widely used in automated equipment data transmission systems
Construction
Conductor: single or stranded bare copper or tinned copper wire conforms to UL758 UL1581 and CSA C22.2 NO.210.02 standard
Insulation: Special hard heat-resistant flame-retardant PVC insulation
Core structure: Two pairs of twists
Shield: aluminum-plastic composite belt + bare copper or tinned copper braid + same specification drain line
Sheath material: mixed 80 degree heat-resistant flame retardant PVC, passed VW-1 flame retardant test standard
Application standards: UL758, UL1581 and CSA C22.2 No.210.2
SPECIFICATIONS
Technical data
Rated voltage: 300V
Rated temperature: 80 degrees
Use of temperature:
Fixed laying: -40 ° C to +80 ° C
Mobile installation: -10 ° C to +80 ° C
Minimum bending radius
Fixed laying: 4×D
Mobile installation: 15×D
Combustion test: Pass UL VW-1, CSA FT1 and JQA F-Mark flame retardant test
Characteristics
◆Good heat resistance, flame retardant and cold resistance
◆ Can withstand certain mechanical external forces and wear resistance
◆Shielding anti-interference characteristics
Number of Core | Conductors |
Braiding/
Shielding
|
Approx Weight
Kg/Km
|
External Diameter
mm
|
1 Pair | 26AWG*2C*1Pair BC | Tinned Copper 100% Coverage | 27.6 | 4.7 |
2 Pairs | 26AWG*2C*2Pairs BC | Tinned Copper 100% Coverage | 45.8 | 6.5 |
3 Pairs | 26AWG*2C*3Pairs BC | Tinned Copper 100% Coverage | 54.4 | 6.9 |
4 Pairs | 26AWG*2C*4Pairs BC | Tinned Copper 100% Coverage | 65.9 | 7.4 |
5 Pairs | 26AWG*2C*5Pairs BC | Tinned Copper 100% Coverage | 76.1 | 8.0 |
6 Pairs | 26AWG*2C*6Pairs BC | Tinned Copper 100% Coverage | 87.7 | 8.7 |
7 Pairs | 26AWG*2C*7Pairs BC | Tinned Copper 100% Coverage | 93.9 | 8.7 |
8 Pairs | 26AWG*2C*8Pairs BC | Tinned Copper 100% Coverage | 106 | 9.3 |
9 Pairs | 26AWG*2C*9Pairs BC | Tinned Copper 100% Coverage | 120 | 10.2 |
10 Pairs | 26AWG*2C*10Pairs BC | Tinned Copper 100% Coverage | 133 | 10.9 |
11 Pairs | 26AWG*2C*11Pairs BC | Tinned Copper 100% Coverage | 142 | 11.2 |
12 Pairs | 26AWG*2C*12Pairs BC | Tinned Copper 100% Coverage | 148 | 11.2 |
13 Pairs | 26AWG*2C*13Pairs BC | Tinned Copper 100% Coverage | 160 | 11.8 |
14 Pairs | 26AWG*2C*14Pairs BC | Tinned Copper 100% Coverage | 166 | 11.8 |
15 Pairs | 26AWG*2C*15Pairs BC | Tinned Copper 100% Coverage | 179 | 12.4 |
16 Pairs | 26AWG*2C*16Pairs BC | Tinned Copper 100% Coverage | 185 | 12.4 |
17 Pairs | 26AWG*2C*17Pairs BC | Tinned Copper 100% Coverage | 199 | 13.0 |
18 Pairs | 26AWG*2C*18Pairs BC | Tinned Copper 100% Coverage | 205 | 13.0 |
19 Pairs | 26AWG*2C*19Pairs BC | Tinned Copper 100% Coverage | 211 | 13.0 |
20 Pairs | 26AWG*2C*20Pairs BC | Tinned Copper 100% Coverage | 221 | 13.4 |
21 Pairs | 26AWG*2C*21Pairs BC | Tinned Copper 100% Coverage | 231 | 13.7 |
22 Pairs | 26AWG*2C*22Pairs BC | Tinned Copper 100% Coverage | 247 | 14.6 |
23 Pairs | 26AWG*2C*23Pairs BC | Tinned Copper 100% Coverage | 262 | 15.2 |
24 Pairs | 26AWG*2C*24Pairs BC | Tinned Copper 100% Coverage | 268 | 15.2 |
25 Pairs | 26AWG*2C*25Pairs BC | Tinned Copper 100% Coverage | 278 | 15.5 |
26 Pairs | 26AWG*2C*26Pairs BC | Tinned Copper 100% Coverage | 284 | 15.5 |
27 Pairs | 26AWG*2C*27Pairs BC | Tinned Copper 100% Coverage | 290 | 15.5 |
28 Pairs | 26AWG*2C*28Pairs BC | Tinned Copper 100% Coverage | 304 | 16.1 |
29 Pairs | 26AWG*2C*29Pairs BC | Tinned Copper 100% Coverage | 310 | 16.1 |
30 Pairs | 26AWG*2C*30Pairs BC | Tinned Copper 100% Coverage | 316 | 16.1 |
31 Pairs | 26AWG*2C*31Pairs BC | Tinned Copper 100% Coverage | 331 | 16.7 |
32 Pairs | 26AWG*2C*32Pairs BC | Tinned Copper 100% Coverage | 337 | 16.7 |
33 Pairs | 26AWG*2C*33Pairs BC | Tinned Copper 100% Coverage | 343 | 16.7 |
34 Pairs | 26AWG*2C*34Pairs BC | Tinned Copper 100% Coverage | 358 | 17.4 |
35 Pairs | 26AWG*2C*35Pairs BC | Tinned Copper 100% Coverage | 364 | 17.4 |
36 Pairs | 26AWG*2C*36Pairs BC | Tinned Copper 100% Coverage | 370 | 17.4 |